One- and Two-Pole, Switchable
Thermal Circuit Breaker / Power SwitchWith Optional Indicator Lamp
Features
•Combines on/off switch and circuit protection in a single unit.• 2 to 20 amp ratings (<2A types available as special order).•One or two pole sensing.
•Lighted or non-lighted rocker actuator in various colors.•Convenient, snap-in mounting.• Optional auxiliary switch available.• Trip-free operation.
Electrical Data @ 25°CCalibration:Breaker will continuously carry 100% of rated load. It may tripbetween 101% and 135%, but must trip at 135% within onehour at +25°C.Dielectric Strength:Over 2,000 volts RMS.Maximum Operating Voltages:50VDC; 250VAC to 400 Hz.Interrupt Capacity:1,000 amps at 50VDC; 250VAC, 60 Hz. and125/250VAC, 400 Hz.1,500 amps at 125/250VAC, 60 Hz.Resettable Overload Capacity:Ten times rated current.Agency ApprovalsW33 series is UL 1077 Recognized as Supplementary Protectors, FileE69543, and CSA Accepted as Supplementary Protectors (ApplianceComponent Protectors), File LR15734. Users should thoroughly review the technical data before selecting a product partnumber. It is recommended that users also seek out the pertinent approvals files ofthe agencies/laboratories and review them to ensure the product meets therequirements for a given application.Mechanical/Environmental DataTermination: Poles 1&2: .250” (6.35mm) quick connect/solder terminals.Opt. Aux. Sw.: .110”(2.79mm) quick connect terminals.Mounting: Snaps into panel from front.Actuator: Rocker or lighted rocker.Shock: 30g tested to IEC 68-2-27, test Ea.Vibration: 8g tested to IEC 68-2-6, test Fc.Switch Endurance Cycling: 50,000 operations at rated load.1,000 operations at 200% rated load.Time vs. Current Trip Curve @ +25°C
1000900
All ModelsAmbient Compensation Chart1.401.30Load Current As A PercentOf Breaker Rating8007006005004003002001000.1
1
10
Correction FactorOverload100%135%200%400%600%800%1000%Trip TimesNo TripTrip in 1 hour3.0 - 33 Sec.0.6 - 10 Sec.0.34 - 5 Sec.0.25 - 2.2 Sec.0.20 - 0.6 Sec.1.201.101.000.900.800.700.60–20–100102030405060Ambient Temperature In Degrees Centigrade (°C)1001000
Time In Seconds
To use this chart:Read up from the ambienttemperature to the curve, and across to find acorrection factor. Multiply the breaker rating by thecorrection factor to determine the compensatedrating. Calculate the overloads in terms of thecompensated rating to use the published trip curve.114reference purposes only.
Dimensions are shown for
Dimensions are in inches over(millimeters) unless otherwisespecified.
Specifications and availabilitysubject to change.
www.tycoelectronics.comTechnical support:
Refer to inside back cover.
Catalog 1308242Issued 3-03 (PDF Rev. 9-05)P&BOrdering InformationTypical Part No. 1.Designator:W = Circuit breaker2.SeriesNumber:33 = Two pole, rocker actuated3.CircuitFunction:S = Pole 1 – Switch only; Pole 2 – Series trip overload sensing.T = Poles 1 & 2 – Series trip overload sensing.SS = Same as S with auxiliary switch on pole 1.TS = Same as T with auxiliary switch on pole 1.D = 2 Pole switching.4.Rocker Color:1 = Black.2 = White.3 = Red. 4 = Amber. 5 = Smoke.N = No light.BW33-S1N1Q-205.Light (available only with White, Red, Amber and Smoke rocker colors):A = 24VDC (Incandescent).B = 120VAC (Neon with resistor).C = 240VAC (Neon with resistor).6.Marking:1 = International I/O.2 = Contrasting I/O stamp (white toggle with black stamp).7.Termination:Q = .250” x .032” (6.35 x .813mm) quick connect / solder terminals.8.AmpRating:2571012151620Consult factory for availability of ratings <2AStock Items – Authorized distributors are more likely to stock the following items.W33-S1N1Q-5W33-S1N1Q-15W33-S1N1Q-20W33-S4B1Q-10W33-S4B1Q-15 W33-T2N1Q-20 W33-T4B1Q-5W33-T4B1Q-10W33-T4B1Q-15 Outline DimensionsROCKER.980(24.89)1.724(43.79)POLE2POLE1SchematicLINE SIDE.850(21.59)I1.890(48.01)1.690(42.93)1.120(28.45)0PANEL CLAMPINGARRANGEMENT.412(10.46).250(6.35)LOAD SIDENEON - ACINCANDESCENT - DCFITS .875 x 1.750 (22.22 x 44.45) PANEL OPENINGFROM .032” - .250”(.813mm - 6.35mm) THICKDimensions are shown forreference purposes only.
Dimensions are in inches over(millimeters) unless otherwisespecified.
Specifications and availabilitysubject to change.
www.tycoelectronics.comTechnical support:
Refer to inside back cover.
115